• direwolf20 7 minutes ago

    Very nice!

    An 8051 with XIP SPI flash - that must be ancient tech.

    • dsrtslnd23 9 minutes ago

      do you know the SPI clock frequency? I am trying to figure out the sampling rate required to reliably capture the trace. That determines the tier of logic analyzer needed I guess.

      • Neywiny 3 minutes ago

        A few ways:

        1. Read the datasheets. Some parts only support certain frequencies, so find the minimum of the master and slave frequencies. 2. Check at boot. Most devices boot slowly for the first few transactions then speed up. So if you saw valid data then aliasing, get a better kit. 3. Start high. I think the fastest serial memory devices cap out at 250 MHz DDR for volatile and 200 for non-volatile. So even a digital discovery (which I think is the best LA for high speed bursts) can deal with it